HL7 FHIR Implementation Guide: DK Core
2.2.0 - release Denmark flag

This page is part of the HL7 FHIR Implementation Guide: DK Core (v2.2.0: Release) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: Telma.FEEDDADADEADBEEF - JSON Representation

Raw json | Download


{
  "resourceType" : "Device",
  "id" : "Telma.FEEDDADADEADBEEF",
  "meta" : {
    "profile" : [
      "http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice"
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"Telma.FEEDDADADEADBEEF\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;Telma.FEEDDADADEADBEEF&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhgDevice.html\">PhgDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier: FE-ED-DA-DA-DE-AD-BE-EF</p><p><b>manufacturer</b>: Trifork</p><p><b>modelNumber</b>: Telma (Android)</p><p><b>type</b>: MDC_MOC_VMS_MDS_AHD: Continua compliant gateway <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531981 &quot;MDC_MOC_VMS_MDS_AHD&quot;)</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352 &quot;MDC_REG_CERT_DATA_CONTINUA_VERSION&quot;)</span></p><p><b>value</b>: 7.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974 &quot;MDC_ID_PROD_SPEC_HW&quot;)</span></p><p><b>value</b>: Samsung Tab S7+ (SM-T970)</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975 &quot;MDC_ID_PROD_SPEC_SW&quot;)</span></p><p><b>value</b>: 1.2.0 (build 2662)</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976 &quot;MDC_ID_PROD_SPEC_FW&quot;)</span></p><p><b>value</b>: Android 12 (API 31)</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353 &quot;MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST&quot;)</span></p><p><b>valueCode</b>: BluetoothLE: Weighing scale <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html\">ContinuaPHD</a>#32783)</span>, BluetoothLE: Blood pressure monitor <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html\">ContinuaPHD</a>#32775)</span>, BluetoothLE: Pulse oximeter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html\">ContinuaPHD</a>#32772)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&amp;Fitness interfaces list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532355 &quot;MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST&quot;)</span></p><p><b>valueCode</b>: observation-upload-fhir: FHIR resource upload <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaHFS.html\">ContinuaHFS</a>#7 &quot;observation-upload-fhir&quot;)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220 &quot;MDC_TIME_SYNC_PROTOCOL&quot;)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532226 &quot;MDC_TIME_SYNC_NTPV4&quot;)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html\">ASN1ToHL7</a>#532354.0)</span></p><p><b>valueCode</b>: Device is NOT regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0136/index.html\">v2 Y/N Indicator</a>#Y)</span></p></blockquote></div>"
  },
  "identifier" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
            "code" : "SYSID",
            "display" : "IEEE 11073 System Identifier"
          }
        ]
      },
      "system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
      "value" : "FE-ED-DA-DA-DE-AD-BE-EF"
    }
  ],
  "manufacturer" : "Trifork",
  "modelNumber" : "Telma (Android)",
  "type" : {
    "coding" : [
      {
        "system" : "urn:iso:std:iso:11073:10101",
        "code" : "531981",
        "display" : "MDC_MOC_VMS_MDS_AHD"
      }
    ],
    "text" : "MDC_MOC_VMS_MDS_AHD: Continua compliant gateway"
  },
  "version" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "532352",
            "display" : "MDC_REG_CERT_DATA_CONTINUA_VERSION"
          }
        ],
        "text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
      },
      "value" : "7.0"
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "531974",
            "display" : "MDC_ID_PROD_SPEC_HW"
          }
        ],
        "text" : "MDC_ID_PROD_SPEC_HW: Hardware version"
      },
      "value" : "Samsung Tab S7+ (SM-T970)"
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "531975",
            "display" : "MDC_ID_PROD_SPEC_SW"
          }
        ],
        "text" : "MDC_ID_PROD_SPEC_SW: Software version"
      },
      "value" : "1.2.0 (build 2662)"
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "531976",
            "display" : "MDC_ID_PROD_SPEC_FW"
          }
        ],
        "text" : "MDC_ID_PROD_SPEC_FW: Firmware version"
      },
      "value" : "Android 12 (API 31)"
    }
  ],
  "property" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "532353",
            "display" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"
          }
        ],
        "text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
              "code" : "32783"
            }
          ],
          "text" : "BluetoothLE: Weighing scale"
        },
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
              "code" : "32775"
            }
          ],
          "text" : "BluetoothLE: Blood pressure monitor"
        },
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
              "code" : "32772"
            }
          ],
          "text" : "BluetoothLE: Pulse oximeter"
        }
      ]
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "532355",
            "display" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST"
          }
        ],
        "text" : "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS",
              "code" : "7",
              "display" : "observation-upload-fhir"
            }
          ],
          "text" : "observation-upload-fhir: FHIR resource upload"
        }
      ]
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "urn:iso:std:iso:11073:10101",
            "code" : "68220",
            "display" : "MDC_TIME_SYNC_PROTOCOL"
          }
        ],
        "text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "urn:iso:std:iso:11073:10101",
              "code" : "532226",
              "display" : "MDC_TIME_SYNC_NTPV4"
            }
          ],
          "text" : "MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization"
        }
      ]
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
            "code" : "532354.0"
          }
        ],
        "text" : "regulation-status"
      },
      "valueCode" : [
        {
          "coding" : [
            {
              "system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
              "code" : "Y"
            }
          ],
          "text" : "Device is NOT regulated"
        }
      ]
    }
  ]
}