This page is part of the HL7 FHIR Implementation Guide: DK Core (v2.2.0: Release) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
<Device xmlns="http://hl7.org/fhir">
<id value="WeightScale.606405FFFECFC604"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: Device</b><a name="WeightScale.606405FFFECFC604"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "WeightScale.606405FFFECFC604" </p><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdDevice.html">PhdDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier: 60-64-05-FF-FE-CF-C6-04, Bluetooth MAC address: 60-64-05-CF-C6-04</p><p><b>manufacturer</b>: A&D Medical </p><p><b>serialNumber</b>: 5180400664</p><p><b>modelNumber</b>: UC-352BLE </p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal health device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><h3>Specializations</h3><table class="grid"><tr><td>-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td>*</td><td>MDC_DEV_SPEC_PROFILE_SCALE: Weighing scale <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#528399 "MDC_DEV_SPEC_PROFILE_SCALE")</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532352 "MDC_REG_CERT_DATA_CONTINUA_VERSION")</span></p><p><b>value</b>: 4.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531974 "MDC_ID_PROD_SPEC_HW")</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531975 "MDC_ID_PROD_SPEC_SW")</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531976 "MDC_ID_PROD_SPEC_FW")</span></p><p><b>value</b>: WSP002_208</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532353 "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST")</span></p><p><b>valueCode</b>: BluetoothLE: Weighing scale <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html">ContinuaPHD</a>#32783)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#68220 "MDC_TIME_SYNC_PROTOCOL")</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532224 "MDC_TIME_SYNC_NONE")</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#532354.0)</span></p><p><b>valueCode</b>: Device is regulated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#68219.0)</span></p><p><b>valueCode</b>: Real time clock is supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#68219.1)</span></p><p><b>valueCode</b>: Setting the real time clock is supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#Y)</span></p></blockquote></div>
</text>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="SYSID"/>
<display value="IEEE 11073 System Identifier"/>
</coding>
</type>
<system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
<value value="60-64-05-FF-FE-CF-C6-04"/>
</identifier>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="BTMAC"/>
<display value="Bluetooth MAC address"/>
</coding>
</type>
<system value="http://hl7.org/fhir/sid/eui-48/bluetooth"/>
<value value="60-64-05-CF-C6-04"/>
</identifier>
<manufacturer value="A&D Medical "/>
<serialNumber value="5180400664"/>
<modelNumber value="UC-352BLE "/>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="65573"/>
<display value="MDC_MOC_VMS_MDS_SIMP"/>
</coding>
<text value="MDC_MOC_VMS_MDS_SIMP: Personal health device"/>
</type>
<specialization>
<systemType>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="528399"/>
<display value="MDC_DEV_SPEC_PROFILE_SCALE"/>
</coding>
<text value="MDC_DEV_SPEC_PROFILE_SCALE: Weighing scale"/>
</systemType>
<version value="1"/>
</specialization>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532352"/>
<display value="MDC_REG_CERT_DATA_CONTINUA_VERSION"/>
</coding>
<text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/>
</type>
<value value="4.1"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531974"/>
<display value="MDC_ID_PROD_SPEC_HW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_HW: Hardware version"/>
</type>
<value value="0.00"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531975"/>
<display value="MDC_ID_PROD_SPEC_SW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_SW: Software version"/>
</type>
<value value="0.00"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531976"/>
<display value="MDC_ID_PROD_SPEC_FW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_FW: Firmware version"/>
</type>
<value value="WSP002_208"/>
</version>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532353"/>
<display value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/>
</type>
<valueCode>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/>
<code value="32783"/>
</coding>
<text value="BluetoothLE: Weighing scale"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="68220"/>
<display value="MDC_TIME_SYNC_PROTOCOL"/>
</coding>
<text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/>
</type>
<valueCode>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532224"/>
<display value="MDC_TIME_SYNC_NONE"/>
</coding>
<text value="MDC_TIME_SYNC_NONE: No time synchronization"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="532354.0"/>
</coding>
<text value="regulation-status"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="N"/>
</coding>
<text value="Device is regulated"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="68219.0"/>
</coding>
<text value="mds-time-capab-real-time-clock"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="Y"/>
</coding>
<text value="Real time clock is supported"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="68219.1"/>
</coding>
<text value="mds-time-capab-set-clock"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="Y"/>
</coding>
<text value="Setting the real time clock is supported"/>
</valueCode>
</property>
</Device>
IG © 2021+ HL7 Denmark. Package hl7.fhir.dk.core#2.2.0 based on FHIR 4.0.1. Generated 2023-05-05
Links: Table of Contents |
QA Report