This page is part of the HL7 FHIR Implementation Guide: DK Core (v3.0.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
{
"resourceType" : "Device",
"id" : "BPMonitor.C4F312FFFE53F2C9",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"BPMonitor.C4F312FFFE53F2C9\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "BPMonitor.C4F312FFFE53F2C9" </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdDevice.html\">PhdDevice</a></p></div><p><b>identifier</b>: Ieee 11073 System Identifier:\u00a0C4-F3-12-FF-FE-53-F2-C9, Bluetooth MAC address:\u00a0<a href=\"http://terminology.hl7.org/3.1.0/NamingSystem-bluetooth-address-identifier.html\">#</a>C4-F3-12-53-F2-C9</p><p><b>manufacturer</b>: A&D Medical </p><p><b>serialNumber</b>: 5181000124</p><p><b>modelNumber</b>: UA-651BLE </p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal health device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><h3>Specializations</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td style=\"display: none\">*</td><td>MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528391 "MDC_DEV_SPEC_PROFILE_BP")</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352 "MDC_REG_CERT_DATA_CONTINUA_VERSION")</span></p><p><b>value</b>: 4.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974 "MDC_ID_PROD_SPEC_HW")</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975 "MDC_ID_PROD_SPEC_SW")</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976 "MDC_ID_PROD_SPEC_FW")</span></p><p><b>value</b>: BLP009_02_005 </p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353 "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST")</span></p><p><b>valueCode</b>: BluetoothLE: Blood pressure monitor <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html\">ContinuaPHD</a>#32775)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220 "MDC_TIME_SYNC_PROTOCOL")</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224 "MDC_TIME_SYNC_NONE")</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html\">ASN1ToHL7</a>#532354.0)</span></p><p><b>valueCode</b>: Device is regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0136/index.html\">v2 Y/N Indicator</a>#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html\">ASN1ToHL7</a>#68219.0)</span></p><p><b>valueCode</b>: Real time clock is supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0136/index.html\">v2 Y/N Indicator</a>#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html\">ASN1ToHL7</a>#68219.1)</span></p><p><b>valueCode</b>: Setting the real time clock is supported <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0136/index.html\">v2 Y/N Indicator</a>#Y)</span></p></blockquote></div>"
},
"identifier" : [
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "SYSID",
"display" : "Ieee 11073 System Identifier"
}
]
},
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "C4-F3-12-FF-FE-53-F2-C9"
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "BTMAC",
"display" : "Bluetooth MAC address"
}
]
},
"system" : "http://hl7.org/fhir/sid/eui-48/bluetooth",
"value" : "C4-F3-12-53-F2-C9"
}
],
"manufacturer" : "A&D Medical ",
"serialNumber" : "5181000124",
"modelNumber" : "UA-651BLE ",
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "65573",
"display" : "MDC_MOC_VMS_MDS_SIMP"
}
],
"text" : "MDC_MOC_VMS_MDS_SIMP: Personal health device"
},
"specialization" : [
{
"systemType" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "528391",
"display" : "MDC_DEV_SPEC_PROFILE_BP"
}
],
"text" : "MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"
},
"version" : "1"
}
],
"version" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532352",
"display" : "MDC_REG_CERT_DATA_CONTINUA_VERSION"
}
],
"text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value" : "4.1"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531974",
"display" : "MDC_ID_PROD_SPEC_HW"
}
],
"text" : "MDC_ID_PROD_SPEC_HW: Hardware version"
},
"value" : "0.00"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531975",
"display" : "MDC_ID_PROD_SPEC_SW"
}
],
"text" : "MDC_ID_PROD_SPEC_SW: Software version"
},
"value" : "0.00"
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531976",
"display" : "MDC_ID_PROD_SPEC_FW"
}
],
"text" : "MDC_ID_PROD_SPEC_FW: Firmware version"
},
"value" : "BLP009_02_005 "
}
],
"property" : [
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532353",
"display" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"
}
],
"text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD",
"code" : "32775"
}
],
"text" : "BluetoothLE: Blood pressure monitor"
}
]
},
{
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68220",
"display" : "MDC_TIME_SYNC_PROTOCOL"
}
],
"text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCode" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532224",
"display" : "MDC_TIME_SYNC_NONE"
}
],
"text" : "MDC_TIME_SYNC_NONE: No time synchronization"
}
]
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
"code" : "532354.0"
}
],
"text" : "regulation-status"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "N"
}
],
"text" : "Device is regulated"
}
]
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
"code" : "68219.0"
}
],
"text" : "mds-time-capab-real-time-clock"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}
],
"text" : "Real time clock is supported"
}
]
},
{
"type" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7",
"code" : "68219.1"
}
],
"text" : "mds-time-capab-set-clock"
},
"valueCode" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}
],
"text" : "Setting the real time clock is supported"
}
]
}
]
}
IG © 2021+ HL7 Denmark. Package hl7.fhir.dk.core#3.0.0 based on FHIR 4.0.1. Generated 2023-12-01
Links: Table of Contents |
QA Report