HL7 FHIR Implementation Guide: DK Core
3.2.0 - release Denmark flag

This page is part of the HL7 FHIR Implementation Guide: DK Core (v3.2.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: Telma.FEEDDADADEADBEEF - TTL Representation

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:Device ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "Telma.FEEDDADADEADBEEF"] ; # 
  fhir:meta [
    ( fhir:profile [
fhir:v "http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice"^^xsd:anyURI ;
fhir:link <http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice>     ] )
  ] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"Telma.FEEDDADADEADBEEF\"> </a><a name=\"hcTelma.FEEDDADADEADBEEF\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device &quot;Telma.FEEDDADADEADBEEF&quot; </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhgDevice.html\">PhgDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier/FE-ED-DA-DA-DE-AD-BE-EF</p><p><b>manufacturer</b>: Trifork</p><p><b>modelNumber</b>: Telma (Android)</p><p><b>type</b>: MDC_MOC_VMS_MDS_AHD: Continua compliant gateway <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531981 &quot;MDC_MOC_VMS_MDS_AHD&quot;)</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532352 &quot;MDC_REG_CERT_DATA_CONTINUA_VERSION&quot;)</span></p><p><b>value</b>: 7.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974 &quot;MDC_ID_PROD_SPEC_HW&quot;)</span></p><p><b>value</b>: Samsung Tab S7+ (SM-T970)</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975 &quot;MDC_ID_PROD_SPEC_SW&quot;)</span></p><p><b>value</b>: 1.2.0 (build 2662)</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware version <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531976 &quot;MDC_ID_PROD_SPEC_FW&quot;)</span></p><p><b>value</b>: Android 12 (API 31)</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532353 &quot;MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST&quot;)</span></p><p><b>valueCode</b>: BluetoothLE: Weighing scale <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html\">ContinuaPHD</a>#32783)</span>, BluetoothLE: Blood pressure monitor <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html\">ContinuaPHD</a>#32775)</span>, BluetoothLE: Pulse oximeter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html\">ContinuaPHD</a>#32772)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&amp;Fitness interfaces list <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532355 &quot;MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST&quot;)</span></p><p><b>valueCode</b>: observation-upload-fhir: FHIR resource upload <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaHFS.html\">ContinuaHFS</a>#7 &quot;observation-upload-fhir&quot;)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220 &quot;MDC_TIME_SYNC_PROTOCOL&quot;)</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532226 &quot;MDC_TIME_SYNC_NTPV4&quot;)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html\">ASN1ToHL7</a>#532354.0)</span></p><p><b>valueCode</b>: Device is NOT regulated <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://hl7.org/fhir/R4/v2/0136/index.html\">v2 Y/N Indicator</a>#Y)</span></p></blockquote></div>"
  ] ; # 
  fhir:identifier ( [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ;
fhir:code [ fhir:v "SYSID" ] ;
fhir:display [ fhir:v "IEEE 11073 System Identifier" ]       ] )     ] ;
fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ;
fhir:value [ fhir:v "FE-ED-DA-DA-DE-AD-BE-EF" ]
  ] ) ; # 
  fhir:manufacturer [ fhir:v "Trifork"] ; # 
  fhir:modelNumber [ fhir:v "Telma (Android)"] ; # 
  fhir:type [
    ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531981" ] ;
fhir:display [ fhir:v "MDC_MOC_VMS_MDS_AHD" ]     ] ) ;
fhir:text [ fhir:v "MDC_MOC_VMS_MDS_AHD: Continua compliant gateway" ]
  ] ; # 
  fhir:version ( [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532352" ] ;
fhir:display [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_VERSION" ]       ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version" ]     ] ;
fhir:value [ fhir:v "7.0" ]
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531974" ] ;
fhir:display [ fhir:v "MDC_ID_PROD_SPEC_HW" ]       ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_HW: Hardware version" ]     ] ;
fhir:value [ fhir:v "Samsung Tab S7+ (SM-T970)" ]
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531975" ] ;
fhir:display [ fhir:v "MDC_ID_PROD_SPEC_SW" ]       ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Software version" ]     ] ;
fhir:value [ fhir:v "1.2.0 (build 2662)" ]
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "531976" ] ;
fhir:display [ fhir:v "MDC_ID_PROD_SPEC_FW" ]       ] ) ;
fhir:text [ fhir:v "MDC_ID_PROD_SPEC_FW: Firmware version" ]     ] ;
fhir:value [ fhir:v "Android 12 (API 31)" ]
  ] ) ; # 
  fhir:property ( [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532353" ] ;
fhir:display [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST" ]       ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list" ]     ] ;
    ( fhir:valueCode [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"^^xsd:anyURI ] ;
fhir:code [ fhir:v "32783" ]       ] ) ;
fhir:text [ fhir:v "BluetoothLE: Weighing scale" ]     ] [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"^^xsd:anyURI ] ;
fhir:code [ fhir:v "32775" ]       ] ) ;
fhir:text [ fhir:v "BluetoothLE: Blood pressure monitor" ]     ] [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"^^xsd:anyURI ] ;
fhir:code [ fhir:v "32772" ]       ] ) ;
fhir:text [ fhir:v "BluetoothLE: Pulse oximeter" ]     ] )
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532355" ] ;
fhir:display [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST" ]       ] ) ;
fhir:text [ fhir:v "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list" ]     ] ;
    ( fhir:valueCode [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"^^xsd:anyURI ] ;
fhir:code [ fhir:v "7" ] ;
fhir:display [ fhir:v "observation-upload-fhir" ]       ] ) ;
fhir:text [ fhir:v "observation-upload-fhir: FHIR resource upload" ]     ] )
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "68220" ] ;
fhir:display [ fhir:v "MDC_TIME_SYNC_PROTOCOL" ]       ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ]     ] ;
    ( fhir:valueCode [
      ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532226" ] ;
fhir:display [ fhir:v "MDC_TIME_SYNC_NTPV4" ]       ] ) ;
fhir:text [ fhir:v "MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization" ]     ] )
  ] [
fhir:type [
      ( fhir:coding [
fhir:system [ fhir:v "http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"^^xsd:anyURI ] ;
fhir:code [ fhir:v "532354.0" ]       ] ) ;
fhir:text [ fhir:v "regulation-status" ]     ] ;
    ( fhir:valueCode [
      ( fhir:coding [
fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v2-0136"^^xsd:anyURI ] ;
fhir:code [ fhir:v "Y" ]       ] ) ;
fhir:text [ fhir:v "Device is NOT regulated" ]     ] )
  ] ) . #