This page is part of the HL7 FHIR Implementation Guide: DK Core (v3.2.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.dk/fhir/core/StructureDefinition/dk-core-producent-id | Version: 3.2.0 | |||
Active as of 2024-05-06 | Computable Name: ProducentId |
Offical MedCom code describing the producer of lab results
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Identifier
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | Identifier | |||
use | 0..1 | code | usual | official | temp | secondary | old (If known) Fixed Value: official | |
system | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID | |
value | 1..1 | string | The value that is unique | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Identifier.type | extensible | Identifier Type Codeshttp://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard |
This structure is derived from Identifier
Differential View
This structure is derived from Identifier
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | Identifier | |||
use | 0..1 | code | usual | official | temp | secondary | old (If known) Fixed Value: official | |
system | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID | |
value | 1..1 | string | The value that is unique | |
Documentation for this format |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | 0..* | Identifier | An identifier intended for computation | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . Fixed Value: official |
type | Σ | 0..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://medcomfhir.dk/ig/terminology/CodeSystem/MedComProducentID |
value | Σ | 1..1 | string | The value that is unique Example General: 123456 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) |
Documentation for this format |
Path | Conformance | ValueSet / Code | URI |
Identifier.use | required | Fixed Value: officialhttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |