HL7 FHIR Implementation Guide: DK Core
3.2.0 - release
This page is part of the HL7 FHIR Implementation Guide: DK Core (v3.2.0: Release) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
<Bundle xmlns="http://hl7.org/fhir">
<id value="ContinuaBundleWithDevice"/>
<type value="transaction"/>
<entry>
<fullUrl value="http://hl7.dk/fhir/core/Patient/Poul"/>
<resource>
<Patient>
<id value="Poul"/>
<meta>
<profile
value="http://hl7.dk/fhir/core/StructureDefinition/dk-core-patient"/>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdPatient"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Patient_Poul"> </a><p><b>Generated Narrative: Patient</b><a name="Poul"> </a><a name="hcPoul"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Patient "Poul" </p><p style="margin-bottom: 0px">Profiles: <a href="StructureDefinition-dk-core-patient.html">Danish Core Patient Profile</a>, <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdPatient.html">PhdPatient</a></p></div><p><b>identifier</b>: National unique individual identifier/3001749995</p><p><b>name</b>: Poul Hansen </p></div>
</text>
<identifier>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
<code value="NI"/>
</coding>
</type>
<system value="urn:oid:1.2.208.176.1.2"/>
<value value="3001749995"/>
</identifier>
<name>
<family value="Hansen"/>
<given value="Poul"/>
</name>
</Patient>
</resource>
<request>
<method value="POST"/>
<url value="Patient"/>
<ifNoneExist value="identifier=urn:oid:1.2.208.176.1.2|3001749995"/>
</request>
</entry>
<entry>
<fullUrl value="http://hl7.dk/fhir/core/Device/Telma.FEEDDADADEADBEEF"/>
<resource>
<Device>
<id value="Telma.FEEDDADADEADBEEF"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhgDevice"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Device_Telma.FEEDDADADEADBEEF"> </a><p><b>Generated Narrative: Device</b><a name="Telma.FEEDDADADEADBEEF"> </a><a name="hcTelma.FEEDDADADEADBEEF"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "Telma.FEEDDADADEADBEEF" </p><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhgDevice.html">PhgDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier/FE-ED-DA-DA-DE-AD-BE-EF</p><p><b>manufacturer</b>: Trifork</p><p><b>modelNumber</b>: Telma (Android)</p><p><b>type</b>: MDC_MOC_VMS_MDS_AHD: Continua compliant gateway <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531981 "MDC_MOC_VMS_MDS_AHD")</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532352 "MDC_REG_CERT_DATA_CONTINUA_VERSION")</span></p><p><b>value</b>: 7.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531974 "MDC_ID_PROD_SPEC_HW")</span></p><p><b>value</b>: Samsung Tab S7+ (SM-T970)</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531975 "MDC_ID_PROD_SPEC_SW")</span></p><p><b>value</b>: 1.2.0 (build 2662)</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531976 "MDC_ID_PROD_SPEC_FW")</span></p><p><b>value</b>: Android 12 (API 31)</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532353 "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST")</span></p><p><b>valueCode</b>: BluetoothLE: Weighing scale <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html">ContinuaPHD</a>#32783)</span>, BluetoothLE: Blood pressure monitor <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html">ContinuaPHD</a>#32775)</span>, BluetoothLE: Pulse oximeter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html">ContinuaPHD</a>#32772)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532355 "MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST")</span></p><p><b>valueCode</b>: observation-upload-fhir: FHIR resource upload <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaHFS.html">ContinuaHFS</a>#7 "observation-upload-fhir")</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#68220 "MDC_TIME_SYNC_PROTOCOL")</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532226 "MDC_TIME_SYNC_NTPV4")</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#532354.0)</span></p><p><b>valueCode</b>: Device is NOT regulated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#Y)</span></p></blockquote></div>
</text>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="SYSID"/>
<display value="IEEE 11073 System Identifier"/>
</coding>
</type>
<system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
<value value="FE-ED-DA-DA-DE-AD-BE-EF"/>
</identifier>
<manufacturer value="Trifork"/>
<modelNumber value="Telma (Android)"/>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531981"/>
<display value="MDC_MOC_VMS_MDS_AHD"/>
</coding>
<text value="MDC_MOC_VMS_MDS_AHD: Continua compliant gateway"/>
</type>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532352"/>
<display value="MDC_REG_CERT_DATA_CONTINUA_VERSION"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/>
</type>
<value value="7.0"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531974"/>
<display value="MDC_ID_PROD_SPEC_HW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_HW: Hardware version"/>
</type>
<value value="Samsung Tab S7+ (SM-T970)"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531975"/>
<display value="MDC_ID_PROD_SPEC_SW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_SW: Software version"/>
</type>
<value value="1.2.0 (build 2662)"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531976"/>
<display value="MDC_ID_PROD_SPEC_FW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_FW: Firmware version"/>
</type>
<value value="Android 12 (API 31)"/>
</version>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532353"/>
<display value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/>
</type>
<valueCode>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/>
<code value="32783"/>
</coding>
<text value="BluetoothLE: Weighing scale"/>
</valueCode>
<valueCode>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/>
<code value="32775"/>
</coding>
<text value="BluetoothLE: Blood pressure monitor"/>
</valueCode>
<valueCode>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/>
<code value="32772"/>
</coding>
<text value="BluetoothLE: Pulse oximeter"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532355"/>
<display value="MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_AHD_CERT_LIST: Continua certified Health&Fitness interfaces list"/>
</type>
<valueCode>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaHFS"/>
<code value="7"/>
<display value="observation-upload-fhir"/>
</coding>
<text value="observation-upload-fhir: FHIR resource upload"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="68220"/>
<display value="MDC_TIME_SYNC_PROTOCOL"/>
</coding>
<text
value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/>
</type>
<valueCode>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532226"/>
<display value="MDC_TIME_SYNC_NTPV4"/>
</coding>
<text value="MDC_TIME_SYNC_NTPV4: NTPV4 time synchronization"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="532354.0"/>
</coding>
<text value="regulation-status"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="Y"/>
</coding>
<text value="Device is NOT regulated"/>
</valueCode>
</property>
</Device>
</resource>
<request>
<method value="POST"/>
<url value="Device"/>
<ifNoneExist
value="identifier=urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680|FE-ED-DA-DA-DE-AD-BE-EF"/>
</request>
</entry>
<entry>
<fullUrl
value="http://hl7.dk/fhir/core/Device/BPMonitor.C4F312FFFE53F2C9"/>
<resource>
<Device>
<id value="BPMonitor.C4F312FFFE53F2C9"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Device_BPMonitor.C4F312FFFE53F2C9"> </a><p><b>Generated Narrative: Device</b><a name="BPMonitor.C4F312FFFE53F2C9"> </a><a name="hcBPMonitor.C4F312FFFE53F2C9"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "BPMonitor.C4F312FFFE53F2C9" </p><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdDevice.html">PhdDevice</a></p></div><p><b>identifier</b>: Ieee 11073 System Identifier/C4-F3-12-FF-FE-53-F2-C9, Bluetooth MAC address/C4-F3-12-53-F2-C9</p><p><b>manufacturer</b>: A&D Medical </p><p><b>serialNumber</b>: 5181000124</p><p><b>modelNumber</b>: UA-651BLE </p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal health device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><h3>Specializations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td style="display: none">*</td><td>MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#528391 "MDC_DEV_SPEC_PROFILE_BP")</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532352 "MDC_REG_CERT_DATA_CONTINUA_VERSION")</span></p><p><b>value</b>: 4.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531974 "MDC_ID_PROD_SPEC_HW")</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531975 "MDC_ID_PROD_SPEC_SW")</span></p><p><b>value</b>: 0.00</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_FW: Firmware version <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#531976 "MDC_ID_PROD_SPEC_FW")</span></p><p><b>value</b>: BLP009_02_005 </p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532353 "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST")</span></p><p><b>valueCode</b>: BluetoothLE: Blood pressure monitor <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ContinuaPHD.html">ContinuaPHD</a>#32775)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#68220 "MDC_TIME_SYNC_PROTOCOL")</span></p><p><b>valueCode</b>: MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#532224 "MDC_TIME_SYNC_NONE")</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: regulation-status <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#532354.0)</span></p><p><b>valueCode</b>: Device is regulated <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#N)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-real-time-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#68219.0)</span></p><p><b>valueCode</b>: Real time clock is supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#Y)</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: mds-time-capab-set-clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#68219.1)</span></p><p><b>valueCode</b>: Setting the real time clock is supported <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#Y)</span></p></blockquote></div>
</text>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="SYSID"/>
<display value="Ieee 11073 System Identifier"/>
</coding>
</type>
<system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
<value value="C4-F3-12-FF-FE-53-F2-C9"/>
</identifier>
<identifier>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaDeviceIdentifiers"/>
<code value="BTMAC"/>
<display value="Bluetooth MAC address"/>
</coding>
</type>
<system value="http://hl7.org/fhir/sid/eui-48/bluetooth"/>
<value value="C4-F3-12-53-F2-C9"/>
</identifier>
<manufacturer value="A&D Medical "/>
<serialNumber value="5181000124"/>
<modelNumber value="UA-651BLE "/>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="65573"/>
<display value="MDC_MOC_VMS_MDS_SIMP"/>
</coding>
<text value="MDC_MOC_VMS_MDS_SIMP: Personal health device"/>
</type>
<specialization>
<systemType>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="528391"/>
<display value="MDC_DEV_SPEC_PROFILE_BP"/>
</coding>
<text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"/>
</systemType>
<version value="1"/>
</specialization>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532352"/>
<display value="MDC_REG_CERT_DATA_CONTINUA_VERSION"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/>
</type>
<value value="4.1"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531974"/>
<display value="MDC_ID_PROD_SPEC_HW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_HW: Hardware version"/>
</type>
<value value="0.00"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531975"/>
<display value="MDC_ID_PROD_SPEC_SW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_SW: Software version"/>
</type>
<value value="0.00"/>
</version>
<version>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="531976"/>
<display value="MDC_ID_PROD_SPEC_FW"/>
</coding>
<text value="MDC_ID_PROD_SPEC_FW: Firmware version"/>
</type>
<value value="BLP009_02_005 "/>
</version>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532353"/>
<display value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"/>
</coding>
<text
value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/>
</type>
<valueCode>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHD"/>
<code value="32775"/>
</coding>
<text value="BluetoothLE: Blood pressure monitor"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="68220"/>
<display value="MDC_TIME_SYNC_PROTOCOL"/>
</coding>
<text
value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/>
</type>
<valueCode>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="532224"/>
<display value="MDC_TIME_SYNC_NONE"/>
</coding>
<text value="MDC_TIME_SYNC_NONE: No time synchronization"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="532354.0"/>
</coding>
<text value="regulation-status"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="N"/>
</coding>
<text value="Device is regulated"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="68219.0"/>
</coding>
<text value="mds-time-capab-real-time-clock"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="Y"/>
</coding>
<text value="Real time clock is supported"/>
</valueCode>
</property>
<property>
<type>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="68219.1"/>
</coding>
<text value="mds-time-capab-set-clock"/>
</type>
<valueCode>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="Y"/>
</coding>
<text value="Setting the real time clock is supported"/>
</valueCode>
</property>
</Device>
</resource>
<request>
<method value="POST"/>
<url value="Device"/>
<ifNoneExist
value="identifier=urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680|C4-F3-12-FF-FE-53-F2-C9"/>
</request>
</entry>
<entry>
<fullUrl value="http://hl7.dk/fhir/core/Observation/BatteryLevel.0944"/>
<resource>
<Observation>
<id value="BatteryLevel.0944"/>
<meta>
<profile
value="http://hl7.dk/fhir/core/StructureDefinition/dk-core-observation"/>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_BatteryLevel.0944"> </a><p><b>Generated Narrative: Observation</b><a name="BatteryLevel.0944"> </a><a name="hcBatteryLevel.0944"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "BatteryLevel.0944" </p><p style="margin-bottom: 0px">Profiles: <a href="StructureDefinition-dk-core-observation.html">Danish Core Observation Profiles</a>, <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdNumericObservation.html">PhdNumericObservation</a></p></div><p><b>Observation Gateway Device</b>: See on this page: Device/Telma.FEEDDADADEADBEEF</p><p><b>status</b>: final</p><p><b>code</b>: MDC_ATTR_VAL_BATT_CHARGE: Battery level <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#67996 "MDC_ATTR_VAL_BATT_CHARGE")</span></p><p><b>subject</b>: See on this page: Patient/Poul</p><p><b>effective</b>: 2023-02-23 10:24:34+0100</p><p><b>performer</b>: See on this page: Patient/Poul</p><p><b>value</b>: 95 %<span style="background: LightGoldenRodYellow"> (Details: UCUM code % = '%')</span></p><p><b>device</b>: See on this page: Device/BPMonitor.C4F312FFFE53F2C9</p></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
<valueReference>🔗
<reference value="Device/Telma.FEEDDADADEADBEEF"/>
</valueReference>
</extension>
<status value="final"/>
<code>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="67996"/>
<display value="MDC_ATTR_VAL_BATT_CHARGE"/>
</coding>
<text value="MDC_ATTR_VAL_BATT_CHARGE: Battery level"/>
</code>
<subject>🔗
<reference value="Patient/Poul"/>
</subject>
<effectiveDateTime value="2023-02-23T10:24:34.563+01:00"/>
<performer>🔗
<reference value="Patient/Poul"/>
</performer>
<valueQuantity>
<value value="95"/>
<system value="http://unitsofmeasure.org"/>
<code value="%"/>
</valueQuantity>
<device>🔗
<reference value="Device/BPMonitor.C4F312FFFE53F2C9"/>
</device>
</Observation>
</resource>
<request>
<method value="POST"/>
<url value="Observation"/>
</request>
</entry>
<entry>
<fullUrl
value="http://hl7.dk/fhir/core/Observation/CoincidentTimeStamp.0222"/>
<resource>
<Observation>
<id value="CoincidentTimeStamp.0222"/>
<meta>
<profile
value="http://hl7.dk/fhir/core/StructureDefinition/dk-core-observation"/>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdCoincidentTimeStampObservation"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_CoincidentTimeStamp.0222"> </a><p><b>Generated Narrative: Observation</b><a name="CoincidentTimeStamp.0222"> </a><a name="hcCoincidentTimeStamp.0222"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "CoincidentTimeStamp.0222" </p><p style="margin-bottom: 0px">Profiles: <a href="StructureDefinition-dk-core-observation.html">Danish Core Observation Profiles</a>, <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdCoincidentTimeStampObservation.html">PhdCoincidentTimeStampObservation</a></p></div><p><b>Observation Gateway Device</b>: See on this page: Device/Telma.FEEDDADADEADBEEF</p><p><b>status</b>: final</p><p><b>code</b>: MDC_ATTR_TIME_ABS: Uses Absolute time clock <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#67975 "MDC_ATTR_TIME_ABS")</span></p><p><b>subject</b>: See on this page: Patient/Poul</p><p><b>effective</b>: 2023-02-23 10:24:34+0100</p><p><b>performer</b>: See on this page: Patient/Poul</p><p><b>value</b>: 2023-02-23 10:24:25+0100</p><p><b>device</b>: See on this page: Device/BPMonitor.C4F312FFFE53F2C9</p></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
<valueReference>🔗
<reference value="Device/Telma.FEEDDADADEADBEEF"/>
</valueReference>
</extension>
<status value="final"/>
<code>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="67975"/>
<display value="MDC_ATTR_TIME_ABS"/>
</coding>
<text value="MDC_ATTR_TIME_ABS: Uses Absolute time clock"/>
</code>
<subject>🔗
<reference value="Patient/Poul"/>
</subject>
<effectiveDateTime value="2023-02-23T10:24:34.467+01:00"/>
<performer>🔗
<reference value="Patient/Poul"/>
</performer>
<valueDateTime value="2023-02-23T10:24:25+01:00"/>
<device>🔗
<reference value="Device/BPMonitor.C4F312FFFE53F2C9"/>
</device>
</Observation>
</resource>
<request>
<method value="POST"/>
<url value="Observation"/>
</request>
</entry>
<entry>
<fullUrl
value="http://hl7.dk/fhir/core/Observation/BloodPressure.Poul.643992"/>
<resource>
<Observation>
<id value="BloodPressure.Poul.643992"/>
<meta>
<profile
value="http://hl7.dk/fhir/core/StructureDefinition/dk-core-observation"/>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdCompoundNumericObservation"/>
<profile
value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/>
<profile value="http://hl7.org/fhir/StructureDefinition/bp"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_BloodPressure.Poul.643992"> </a><p><b>Generated Narrative: Observation</b><a name="BloodPressure.Poul.643992"> </a><a name="hcBloodPressure.Poul.643992"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "BloodPressure.Poul.643992" </p><p style="margin-bottom: 0px">Profiles: <a href="StructureDefinition-dk-core-observation.html">Danish Core Observation Profiles</a>, <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdCompoundNumericObservation.html">PhdCompoundNumericObservation</a>, <a href="http://hl7.org/fhir/R4/vitalsigns.html">Vital Signs Profile</a>, <a href="http://hl7.org/fhir/R4/bp.html">Observation Blood Pressure Profile</a></p></div><p><b>Observation Gateway Device</b>: See on this page: Device/Telma.FEEDDADADEADBEEF</p><p><b>identifier</b>: C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-150020-118-266016-87-266016-99-266016-20230223T102408.00</p><p><b>status</b>: final</p><p><b>category</b>: Vital signs <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-observation-category.html">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: MDC_PRESS_BLD_NONINV: Blood Pressure <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#85354-9 "Blood pressure panel with all children optional"; <a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#150020 "MDC_PRESS_BLD_NONINV"; unknown#ZZ3170 "Hjemmeblodtryksmåling udført af patienten")</span></p><p><b>subject</b>: See on this page: Patient/Poul</p><p><b>effective</b>: 2023-02-23 10:24:08+0100</p><p><b>performer</b>: See on this page: Patient/Poul</p><p><b>device</b>: See on this page: Device/BPMonitor.C4F312FFFE53F2C9</p><p><b>derivedFrom</b>: See on this page: Observation/CoincidentTimeStamp.0222</p><blockquote><p><b>component</b></p><p><b>code</b>: MDC_PRESS_BLD_NONINV_SYS: Systolic Blood Pressure <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#8480-6 "Systolic blood pressure"; <a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#150021 "MDC_PRESS_BLD_NONINV_SYS"; medcom-observation-codes#MCS88019 "Arm—Blodtryk(systolisk) hjemme; tryk = ? mmHg")</span></p><p><b>value</b>: 118 mmHg<span style="background: LightGoldenRodYellow"> (Details: UCUM code mm[Hg] = 'mm[Hg]')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: MDC_PRESS_BLD_NONINV_DIA: Diastolic Blood Pressure <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#8462-4 "Diastolic blood pressure"; <a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#150022 "MDC_PRESS_BLD_NONINV_DIA"; medcom-observation-codes#MCS88020 "Arm—Blodtryk(diastolisk) hjemme; tryk = ? mmHg")</span></p><p><b>value</b>: 87 mmHg<span style="background: LightGoldenRodYellow"> (Details: UCUM code mm[Hg] = 'mm[Hg]')</span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: MDC_PRESS_BLD_NONINV_MEAN: Mean Blood Pressure <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#150023 "MDC_PRESS_BLD_NONINV_MEAN")</span></p><p><b>value</b>: 99 mmHg<span style="background: LightGoldenRodYellow"> (Details: UCUM code mm[Hg] = 'mm[Hg]')</span></p></blockquote></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
<valueReference>🔗
<reference value="Device/Telma.FEEDDADADEADBEEF"/>
</valueReference>
</extension>
<identifier>
<value
value="C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-150020-118-266016-87-266016-99-266016-20230223T102408.00"/>
</identifier>
<status value="final"/>
<category>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/observation-category"/>
<code value="vital-signs"/>
<display value="Vital signs"/>
</coding>
</category>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="85354-9"/>
<display value="Blood pressure panel with all children optional"/>
</coding>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="150020"/>
<display value="MDC_PRESS_BLD_NONINV"/>
</coding>
<coding>
<system value="urn:oid:1.2.208.176.2.4"/>
<code value="ZZ3170"/>
<display value="Hjemmeblodtryksmåling udført af patienten"/>
</coding>
<text value="MDC_PRESS_BLD_NONINV: Blood Pressure"/>
</code>
<subject>🔗
<reference value="Patient/Poul"/>
</subject>
<effectiveDateTime value="2023-02-23T10:24:08+01:00"/>
<performer>🔗
<reference value="Patient/Poul"/>
</performer>
<device>🔗
<reference value="Device/BPMonitor.C4F312FFFE53F2C9"/>
</device>
<derivedFrom>🔗
<reference value="Observation/CoincidentTimeStamp.0222"/>
</derivedFrom>
<component>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="8480-6"/>
<display value="Systolic blood pressure"/>
</coding>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="150021"/>
<display value="MDC_PRESS_BLD_NONINV_SYS"/>
</coding>
<coding>
<system
value="http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes"/>
<code value="MCS88019"/>
<display value="Arm—Blodtryk(systolisk) hjemme; tryk = ? mmHg"/>
</coding>
<text value="MDC_PRESS_BLD_NONINV_SYS: Systolic Blood Pressure"/>
</code>
<valueQuantity>
<value value="118"/>
<unit value="mmHg"/>
<system value="http://unitsofmeasure.org"/>
<code value="mm[Hg]"/>
</valueQuantity>
</component>
<component>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="8462-4"/>
<display value="Diastolic blood pressure"/>
</coding>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="150022"/>
<display value="MDC_PRESS_BLD_NONINV_DIA"/>
</coding>
<coding>
<system
value="http://medcomfhir.dk/ig/terminology/CodeSystem/medcom-observation-codes"/>
<code value="MCS88020"/>
<display
value="Arm—Blodtryk(diastolisk) hjemme; tryk = ? mmHg"/>
</coding>
<text value="MDC_PRESS_BLD_NONINV_DIA: Diastolic Blood Pressure"/>
</code>
<valueQuantity>
<value value="87"/>
<unit value="mmHg"/>
<system value="http://unitsofmeasure.org"/>
<code value="mm[Hg]"/>
</valueQuantity>
</component>
<component>
<code>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="150023"/>
<display value="MDC_PRESS_BLD_NONINV_MEAN"/>
</coding>
<text value="MDC_PRESS_BLD_NONINV_MEAN: Mean Blood Pressure"/>
</code>
<valueQuantity>
<value value="99"/>
<unit value="mmHg"/>
<system value="http://unitsofmeasure.org"/>
<code value="mm[Hg]"/>
</valueQuantity>
</component>
</Observation>
</resource>
<request>
<method value="POST"/>
<url value="Observation"/>
<ifNoneExist
value="identifier=C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-150020-118-266016-87-266016-99-266016-20230223T102408.00"/>
</request>
</entry>
<entry>
<fullUrl
value="http://hl7.dk/fhir/core/Observation/HeartRate.Poul.1974654"/>
<resource>
<Observation>
<id value="HeartRate.Poul.1974654"/>
<meta>
<profile
value="http://hl7.dk/fhir/core/StructureDefinition/dk-core-observation"/>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdNumericObservation"/>
<profile
value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/>
<profile value="http://hl7.org/fhir/StructureDefinition/heartrate"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_HeartRate.Poul.1974654"> </a><p><b>Generated Narrative: Observation</b><a name="HeartRate.Poul.1974654"> </a><a name="hcHeartRate.Poul.1974654"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "HeartRate.Poul.1974654" </p><p style="margin-bottom: 0px">Profiles: <a href="StructureDefinition-dk-core-observation.html">Danish Core Observation Profiles</a>, <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdNumericObservation.html">PhdNumericObservation</a>, <a href="http://hl7.org/fhir/R4/vitalsigns.html">Vital Signs Profile</a>, <a href="http://hl7.org/fhir/R4/heartrate.html">Observation Heart Rate Profile</a></p></div><p><b>Observation Gateway Device</b>: See on this page: Device/Telma.FEEDDADADEADBEEF</p><p><b>identifier</b>: C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-149546-93-{beat}/min-20230223T102408.00</p><p><b>status</b>: final</p><p><b>category</b>: Vital signs <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.5.0/CodeSystem-observation-category.html">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: MDC_PULS_RATE_NON_INV: Heart rate <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#8867-4 "Heart rate"; <a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#149546 "MDC_PULS_RATE_NON_INV"; unknown#NPU21692 "Heart—Systole; frequency = ? × 1/min")</span></p><p><b>subject</b>: See on this page: Patient/Poul</p><p><b>effective</b>: 2023-02-23 10:24:08+0100</p><p><b>performer</b>: See on this page: Patient/Poul</p><p><b>value</b>: 93 bpm<span style="background: LightGoldenRodYellow"> (Details: UCUM code /min = '/min')</span></p><p><b>device</b>: See on this page: Device/BPMonitor.C4F312FFFE53F2C9</p><p><b>derivedFrom</b>: See on this page: Observation/CoincidentTimeStamp.0222</p></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
<valueReference>🔗
<reference value="Device/Telma.FEEDDADADEADBEEF"/>
</valueReference>
</extension>
<identifier>
<value
value="C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-149546-93-{beat}/min-20230223T102408.00"/>
</identifier>
<status value="final"/>
<category>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/observation-category"/>
<code value="vital-signs"/>
<display value="Vital signs"/>
</coding>
</category>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="8867-4"/>
<display value="Heart rate"/>
</coding>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="149546"/>
<display value="MDC_PULS_RATE_NON_INV"/>
</coding>
<coding>
<system value="urn:oid:1.2.208.176.2.1"/>
<code value="NPU21692"/>
<display value="Heart—Systole; frequency = ? × 1/min"/>
</coding>
<text value="MDC_PULS_RATE_NON_INV: Heart rate"/>
</code>
<subject>🔗
<reference value="Patient/Poul"/>
</subject>
<effectiveDateTime value="2023-02-23T10:24:08+01:00"/>
<performer>🔗
<reference value="Patient/Poul"/>
</performer>
<valueQuantity>
<value value="93"/>
<unit value="bpm"/>
<system value="http://unitsofmeasure.org"/>
<code value="/min"/>
</valueQuantity>
<device>🔗
<reference value="Device/BPMonitor.C4F312FFFE53F2C9"/>
</device>
<derivedFrom>🔗
<reference value="Observation/CoincidentTimeStamp.0222"/>
</derivedFrom>
</Observation>
</resource>
<request>
<method value="POST"/>
<url value="Observation"/>
<ifNoneExist
value="identifier=C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-149546-93-{beat}/min-20230223T102408.00"/>
</request>
</entry>
<entry>
<fullUrl
value="http://hl7.dk/fhir/core/Observation/BloodPressureStatus.Poul.133527"/>
<resource>
<Observation>
<id value="BloodPressureStatus.Poul.133527"/>
<meta>
<profile
value="http://hl7.dk/fhir/core/StructureDefinition/dk-core-observation"/>
<profile
value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdBitsEnumerationObservation"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><a name="Observation_BloodPressureStatus.Poul.133527"> </a><p><b>Generated Narrative: Observation</b><a name="BloodPressureStatus.Poul.133527"> </a><a name="hcBloodPressureStatus.Poul.133527"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "BloodPressureStatus.Poul.133527" </p><p style="margin-bottom: 0px">Profiles: <a href="StructureDefinition-dk-core-observation.html">Danish Core Observation Profiles</a>, <a href="http://hl7.org/fhir/uv/phd/STU1/StructureDefinition-PhdBitsEnumerationObservation.html">PhdBitsEnumerationObservation</a></p></div><p><b>Observation Gateway Device</b>: See on this page: Device/Telma.FEEDDADADEADBEEF</p><p><b>identifier</b>: C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-8410608-8192-20230223T102408.00</p><p><b>status</b>: final</p><p><b>code</b>: MDC_BLOOD_PRESSURE_MEASUREMENT_STATUS: Blood Pressure measurement problem <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#8410608 "MDC_BLOOD_PRESSURE_MEASUREMENT_STATUS")</span></p><p><b>subject</b>: See on this page: Patient/Poul</p><p><b>effective</b>: 2023-02-23 10:24:08+0100</p><p><b>performer</b>: See on this page: Patient/Poul</p><p><b>device</b>: See on this page: Device/BPMonitor.C4F312FFFE53F2C9</p><p><b>derivedFrom</b>: </p><ul><li>See on this page: Observation/CoincidentTimeStamp.0222</li><li>See on this page: Observation/BloodPressure.Poul.643992</li></ul><h3>Components</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Code</b></td><td><b>Value[x]</b></td></tr><tr><td style="display: none">*</td><td>irregular-pulse <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/uv/phd/STU1/CodeSystem-ASN1ToHL7.html">ASN1ToHL7</a>#8410608.2)</span></td><td>Irregular pulse was detected <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://hl7.org/fhir/R4/v2/0136/index.html">v2 Y/N Indicator</a>#Y)</span></td></tr></table></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/observation-gatewayDevice">
<valueReference>🔗
<reference value="Device/Telma.FEEDDADADEADBEEF"/>
</valueReference>
</extension>
<identifier>
<value
value="C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-8410608-8192-20230223T102408.00"/>
</identifier>
<status value="final"/>
<code>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="8410608"/>
<display value="MDC_BLOOD_PRESSURE_MEASUREMENT_STATUS"/>
</coding>
<text
value="MDC_BLOOD_PRESSURE_MEASUREMENT_STATUS: Blood Pressure measurement problem"/>
</code>
<subject>🔗
<reference value="Patient/Poul"/>
</subject>
<effectiveDateTime value="2023-02-23T10:24:08+01:00"/>
<performer>🔗
<reference value="Patient/Poul"/>
</performer>
<device>🔗
<reference value="Device/BPMonitor.C4F312FFFE53F2C9"/>
</device>
<derivedFrom>🔗
<reference value="Observation/CoincidentTimeStamp.0222"/>
</derivedFrom>
<derivedFrom>
<reference value="Observation/BloodPressure.Poul.643992"/>
</derivedFrom>
<component>
<code>
<coding>
<system
value="http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7"/>
<code value="8410608.2"/>
</coding>
<text value="irregular-pulse"/>
</code>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
<code value="Y"/>
</coding>
<text value="Irregular pulse was detected"/>
</valueCodeableConcept>
</component>
</Observation>
</resource>
<request>
<method value="POST"/>
<url value="Observation"/>
<ifNoneExist
value="identifier=C4F312FFFE53F2C9-3001749995-urn:oid:1.2.208.176.1.2-8410608-8192-20230223T102408.00"/>
</request>
</entry>
</Bundle>